Structural Loads and Foundations
Check and size rectangular isolated and combined footings, then generate a calculation report and drawings.
Engineering review edition. Verify the inputs and applicable code provisions before construction. Complete biaxial anchor checks where applicable.
Project and design basis
Workflow · Enter soil data and support reactions for service (S) and strength (U) cases. Design the footing or check its dimensions, then save each footing before generating the project report.
Footing plan
To add an item, select its placement tool and click its location. To delete an item, select Delete, click the item, and confirm.
Select a support or the footing outline to edit it.
Loads and supports
Calculate unfactored wind cases for a fixed object on one support. Use a combined pressure coefficient from the project wind study and measure the height from the reaction reference level.
Apply project factors to wind cases
Enter D and W factors from the project design basis. Add other required load cases separately.
Define one row per support. X and Y are offsets from the footing center. The reaction reference height above the footing base is used to transfer moments.
Paste supports from Excel or CSV
Use one row per support per combination. S is service and U is strength. Enter the action on the foundation with N positive in compression and moments following the right-hand rule. The self-weight factor applies to the footing and permanent backfill.
Paste loads from Excel or CSV
Footing, soil and materials
Leave width, length, thickness and concrete strength blank to size the footing automatically. Enter these values to check a specific design.
Settlement and geotechnical report
Estimate immediate settlement under mean net service pressure. Use the influence factors from the geotechnical report. Long-term and differential settlement require separate analysis.
Paste soil layers from Excel or CSV
Steel section, base plate and anchors
Enter documented member and anchor design strengths. The plate model supports four symmetric anchors for group shear and torsion with uniaxial bending.
Reinforcement criteria and external checks
Use factors from the applicable design code. For external checks enter documented demand and design resistance in the same unit. Complete the independent checks before finalizing the design.
Sizing considers bearing, sliding and contact. Set optional geometric limits to constrain the search.
Section properties may be entered for each support to calculate elastic axial and bending stresses at the reaction reference level.